Acorn 180 Stairlift Error Code H7 Correct Diagnosis, Repair Diary, Power Failure, Cause of H7 Determined,

  • 8 months ago
Acorn 180 Stairlift Error Code H7 Correct Diagnosis, Repair Diary, Power Failure without Warning, True Underlying Cause of H7 Errorcode is Determined by .5V Non-Contact Voltage Sensor and HiRes Thermal Imager.

The H7 error code is usually just the visible display in a stack of several error codes. The Facebook Acorn Users Group has at least two “explanations” or interpretations that are incorrect, not even taking in consideration the four Acorn 180 versions of Acorn curved stairlifts that I have repaired or installed. See my 50+ stairlift repair video diaries since circa 2007. Am not an Acorn employee, just an independent who enjoys the puzzle, puzzles of broken stairlifts and mobility disability scooters. This Facebook group has resulted in even more business for me as laypeople are missing several key cautions and tools. They will also hurt or poison themselves as shown on three or more of my repair diaries. One Facebook poster turned a Cdn$300 battery replacement into a complete disaster, likely a write off. The procedure to clear H7 and its antecedent relative the F7, requires a repaired platform, first. Btw, disassebled stairlifts have almost zero buyers in Metro Vancouver. I have a solution for sellers. Which also helps buyers with no cash.